Penetrant sensitivity (pt)

Глоссарий терминов по технологиям неразрушающего контроля (NDT)
    Penetrant sensitivity is the ability of the penetrant, processing technique, and developer to detect surface-connected discontinuities and provide an indication visible to the unaided eye.




Sensitivity, английский
  1. Change in the response of a measuring instrument divided by the corresponding change in the stimulus (1)

  2. The ratio of the output of an instrument to the input (i.e. -gain).

  3. Defines the smallest signal detectable in the presence of systems noise

  4. In television, a factor expressing the incident illumination upon a specified scene required to produce a specified picture signal at the output terminals of a television camera.

  5. For a camera usually specified in lux to provide indication of light level required to gain a full video signal from the camera.

  6. A measure of the amount of light required to provide a standard video signal. sensitivity values are stated in lux (see lux) or foot-candles.

  7. Lens iris aperture required to provide a video output signal of standard level at a specified light input. in general, sensitivity is measured using an 89.9% reflectance grey scale chart illuminated by a 3200? k illuminance at 2000 lux (color camera) or 400 lux (b/w camera), for a video output level of 100%.

  8. 1. the fact of being able to detect and respond to an outside stimulus 2. the rate of positive responses in a test from persons with a specific disease. a high rate of sensitivity means a low rate of people being incorrectly classed as negative. compare specificity

  9. Чувствительность; сенситивность; восприимчивость специфически измененная реактивность. вероятность возникновения реакции на введение антигенов. ср. susceptibility (восприимчивость (к болезни)).

  10. The sensitivity of classification rule is a measure of its ability to correctly classify observations into a particular category. it is defined to be the ratio of the number of true positives to the number of positives in a test set. this value is usually inversely related to the specificity of the test for a given set of data and a particular classification rule. note that this measure is different from the positive predictive value of a rule, which is a measure of the probability that a positive is a true positive. if multiple classification categories exist, each category will have its own sensitivity, specificity, and positive predictive value. see also: positive predictive value, specificity.

  11. Чувствительность: a) различие в концентрации аналита, соответствующее наименьшему обнару-живаемому различию в реакции метода. представляется наклоном калибровоч-ной кривой. иногда ошибочно используется для обозначения предела обнаружения. b) частота истинно положительных результатов, полученных при испытании проб, в которых, насколько известно, содержится аналит [55]. c) отношение изменения показаний измерительного прибора к соответствую-щему изменению измеряемой величины. измеряемой величиной может быть, например, количество исследуемого вещества, содержащееся в пробе.

  12. Чувствительность. в сенсорном анализе — способность различать, идентифицировать и/или дифференцировать (качественно и/или количественно) один или более раздражителей с помощью органов чувств (предварительный стандарт мос, 12). в аналитической химии — чувствительность метода, которая (для простого-метода)- характеризуется наклоном калибровочной кривой, т. е. является дифференциалом измеряемой величины по отношению к концентрации dx/dc. чувствительность не следует путать с наименьшим количеством или наиболее низкой концентрацией, которые можно обнаружить с помощью данного метода; правильный термин для обозначения этого понятия — предел чувствительности (см. limit of detection).

  13. The output of a microphone in volts for a given input in sound pressure level. sensitivity can also mean the sound pressure level (spl) a loudspeaker produces at one meter when driven with one watt of pink noise.

  14. The degree of confidentiality of an e-mail message or calendar item, ranging from normal to confidential.

  15. The significance level that must be reached before a notification is sent.

  16. Чувствительность:

  17. Measure of a sensor’s ability to detect small signals. see resolution.

  18. Ability of a sensor or system to distinguish a signal or indication from background noise. see also probability of detection.

  19. Ability of a sensor or system to distinguish a signal or indication from background noise. see also probability of detection. si (international system of units): international measurement system in which the following seven

  20. (1) performance characteristic of a penetrant system, of a developer, or of an entire penetrant process that provides a relative measure of the ability to detect discontinuities. (2) enumerated level of performance of a penetrant system determined by applying standardized processing procedures on reference standards with known defects. (3) ability of a sensor or system to distinguish a signal or indication from background noise. compare probability of detection.

  21. Probability of detection.

  22. Ability of signal to change with small changes of measured quantity.


Processing, английский
  1. Обработка (напр. данных); технология

  2. N обработка cognitive ~ когнитивная обработка language ~ когн.

  3. Обработка ~ of materials обработка [переработка] материалов

  4. A language originally designed for artists to allow them to do simple graphical design programs in a movie like paradigm.

  5. The preparation or packaging of fish to render it suitable for human consumption, retail sale, industrial use, or long-term storage, including but not limited to cooking, canning, smoking, salting, drying, filleting, freezing, or rendering into meal or oil, but not heading and gutting unless additional preparation is done.

  6. Under the gdpr, “processing” is any operation that is performed on personal data. this includes collection, recording, organisation, structuring, storage, adaptation, alteration, dissemination, erasure or destruction.


Indication, английский
  1. Индикация

  2. A situation or sign which suggests that a specific treatment should be given or that a condition has a particular cause  sulpha drugs have been replaced by antibiotics in many indications.  contraindication

  3. (1) notice given by a dealer (through autex) or customer of an interest in buying or selling stock, sometimes including specific volume and price; (2) approximation of where a specialist sees buy and sell interest to tighten the range to an opening price.

  4. Выражение интереса (бирж.)

  5. In nondestructive inspection, a response or evidence of a response, that requires interpretation to determine its significance.

  6. Nondestructive test response that requires interpretation to determine its relevance. these include such things as meter deflections, shadows on radiographs, blips on screens, or localized discolorations on surfaces. see also defect; discontinuity; indication, false; indication, nonrelevant. indication, discontinuity: visible evidence of a material discontinuity. subsequent interpretation is required to determine the significance of an indication. indication, false: test indication that could be interpreted as originating from a discontinuity where no discontinuity exists. compare defect; ghost; indication, nonrelevant. false indications are an economic liability for inspection because they must be investigated. indication, nonrelevant: indication due to misapplied or improper testing. may also be an indication caused by an actual discontinuity that does not affect the usability of the test object (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a nonrelevant indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size, shape, orientation, or location.

  7. Nondestructive test response that requires interpretation to determine its relevance.4 see also defect; discontinuity; false indication; nonrelevant indication. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect.1 test response caused by geometry or by a physical condition that is not a discontinuity. indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.1

  8. Nondestructive test response that requires interpretation to determine its relevance. compare defect; discontinuity; indication, false; indication, nonrelevant. indication, false: (1) test indication that could be interpreted as originating from a discontinuity but that actually originates where no discontinuity exists in the test object. (2) indication due to misapplied or improper testing. compare indication, nonrelevant; defect. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect. test response caused by geometry or by a physical condition that is not a discontinuity (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.

  9. Nondestructive test response that requires interpretation to determine its relevance. compare defect; discontinuity. see also indication, false; indication, nonrelevant. indication, false: (1) test indication that could be interpreted as originating from a discontinuity but that actually originates where no discontinuity exists in the test object. (2) indication due to misapplied or improper testing. compare indication, nonrelevant. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect. test response caused by geometry or by a physical condition that is not a discontinuity (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.

  10. Nondestructive test equipment response to a discontinuity that requires interpretation to determine its relevance.4 in magnetic particle testing, a visible accumulation of magnetic particles that serves as evidence of a magnetic leakage field.

  11. Defect, discontinuity, false indication and nonrelevant indication. induced current magnetization: noncontact means for testing delicate ring shaped objects for circumferential discontinuities. the technique is based on the fact that a time varying current passing through an internal conductor, often a soft iron or laminated core, self-induces an encircling magnetic field. this time varying magnetic field will induce a secondary current circling through the ring. this secondary current then self-induces the toroidal magnetic field used for testing.

  12. Nondestructive test equipment response to a reflector, requiring interpretation to determine its relevance. compare crack; defect; discontinuity; indication, false.10 indication, discontinuity: visible evidence of a material discontinuity. subsequent interpretation is required to determine the indication’s significance.10 indication, false: test indication that originates where no discontinuity exists in the test object. compare defect; indication, nonrelevant.10 indication, nonrelevant: indication possibly caused by an actual discontinuity that does not affect the usability of the test object (a change of section, for instance) or that is smaller than a relevant indication. compare indication, false and indication, relevant.10 indication, relevant: indication from a discontinuity (as opposed to a nonrelevant indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size, shape, orientation or location. compare indication, nonrelevant.10,19


Dye penetrant, английский
  1. Penetrant with dye added that makes it readily visible in light.

  2. See color contrast penetrant. e


Fire scale, английский
    Oxide subscale formed just under the surface of certain alloys when they are annealed in air.